Chapter 4: Service & maintenance
66 Maintenance
DSC self test
To run a control routine DSC self test, do as follows:
1. Press the soft key SETUP. If it is not in the display, press the soft key MORE
until SETUP appears.
2. Press the arrow soft key or to advance to DSC SETUP.
3. Turn the selector wheel knob to select DSC Self Test. Press and turn the
selector wheel knob to select RUN.
The test will check the ability to encode/decode DSC signalling on RF level.
The radio will automatically transmit a DSC safety test call to its own MMSI
number without enabling the transmitter power amplifier. In parallel the
radio decodes and compares the received call to be the same as the
transmitted.
The display shows the result of
the test.
4. Press the soft key OK to
acknowledge the test result and
resume normal operation.
Troubleshooting guide
DSC loopback
test passed
TEST RESULT
DSC loopback
test FAILED
TEST RESULT
Action Symptom Remedy
The radio will
not turn on
The display is
empty.
Check if power is present.
Check fuse which is placed in the + supply
wire.
Check performance of power supply if
connected to one.